Koneet ja laitteet

2006 Hapenpoistolaitteisto prosessivedelle Alfa Laval ALDOX-P 150 hl

: 8442020

Hapenpoistolaitteisto Alfa Laval ALDOX-P 150 hl olutpanimon prosessiveden käsittelyyn, vm 2006. ALDOX laitteisto on täysin automatisoitu ja valmis välittömääm köyttöön. Laitteistossa on automaattinen pesutoiminto (CIP)

Technical Details

  • Valmistaja Alfa Laval
  • Valmistajan tyyppimerkintä How DAW ALDOX-P 150 hl
  • Valmistusvuosi 2006
  • Kapasiteetti 150 hl/h
  • Tuoteryhmä Hapenpoisto olutpanimon prosessivedesta
  • Residual oxygen content  max 0,02 ppm
  • Water inlet temperature 8 -15 °C
  • Pasteurization temperature 72 °C
  • Water outlet temperature 2 °C
  • Cooling media   Prop. Glycol 25%
  • Heating media Steam, 3 bar dry saturated
  • Electric power 15 kW / 3x400V / 50 Hz  
  • Water Hot Deaeration Alfa Laval ALDOX-P 150 HL
  • Water Hot Deaeration Alfa Laval ALDOX-P 150 HL
  • Water Hot Deaeration Alfa Laval ALDOX-P 150 HL
  • Water Hot Deaeration Alfa Laval ALDOX-P 150 HL
  • Water Hot Deaeration Alfa Laval ALDOX-P 150 HL
  • Water Hot Deaeration Alfa Laval ALDOX-P 150 HL

Water Deaeration Plant ALDOX-P 150 HL with Pasteurization

Hot deaeration plant ALDOX-P 150 HLwas made by Alfa Laval in year 2006 and it is designed for produce air free, deaerated water for brewing.  ALDOX Plant is fully automatic, self-contained, ready for operation and it has on built CIP nozzles for automatic cleaning. This deaeration technology results in exceptionally efficient oxygen removal, with very low gas consumption. Water is also pasteurized at 72 °C during the process and do not need pasteurization afterwards. During oxygen removal 95% or more of the stripping gas entering the column is dissolved into the water, which reduces the need for additional carbonation of products for production of such as high-gravity blended beer. The high desorption of oxygen is achieved by using carbon dioxide or nitrogen oxide as the stripping gas over a packed bed, at atmospheric pressure. Water is routed via the liquid distributor to the top of the column and travels downward countercurrent with the CO2 / N2 . ALDOX systems enable you to keep oxygen levels down to as little as 0,02 ppm

List of main equipment:

  1. ALDOX-P Deaeration Module
  2. Stripping Column, AISI 304
  3. Plate Heat Exchanger FRONT LINE 8-RM, 3 sections, AISI 316
  4. Balance Tank BTD-350, AISI 304
  5. Sanitary Centrifugal Pump LKH, frequency-controlled speed
  6. Centrifugal Pump LKH for cooling media
  7. Control Paned with Siemens C7 PLC and TP 270 operator interface
  8. Set of valves, process indicators and piping